Periodic Pulse (PP) and Periodic Pulse Reverse (PPR) Power Supplies - DuraPulse™
Source: TecNu, Inc.
TECNU periodic pulse (PP) and periodic pulse reverse (PPR) power supplies enable control of the On-Time (Forward),
TECNU periodic pulse (PP) and periodic pulse reverse (PPR) power supplies enable control of the On-Time (Forward), Off-Time (Reverse), On-Amplitude (Forward) and Reverse Amplitude (if applicable). The additional control variables over DC, provide control over the electrochemical process by affecting such properties as the diffusion layer, grain size and nucleation. Proper selection of these variables, yield deposit results which can not be attained by conventional direct current at comparable deposition rates.
WAVEFORMS:
Periodic Pulse (PP) and DC
TYPICAL APPLICATIONS: Precious & semiprecious metals, flatter
deposit, electroforming, PCB (non throwing power applications), laboratory use,
and the electronics industry in general.
12VDC
standard models (Other models available upon request)
|
|||||||||||
Model
Numer
|
Max.
Avg Amps
|
Max.
Peak Amps
|
Amps
resolution
|
Volts
|
Volts
resolution
|
VAC
input
|
Phase
|
Digital
LCD Meters
|
Menu
Driven Control
|
Totalizer
|
Front
Panel Calibration
|
PP5/10/12-1Z
|
10
|
10
|
.001/.01
|
12
|
0.1
|
120
|
1
|
S
|
S
|
Amp-Min
|
S
|
PP150-250/12-3
|
150
|
250
|
1
|
12
|
0.1
|
208
|
3
|
S
|
S
|
Amp-Min
|
S
|
PP300-500/12-3
|
300
|
500
|
1
|
12
|
0.1
|
208
|
3
|
S
|
S
|
Amp-Min
|
S
|
S=Standard
GENERAL SPECIFICATIONS FOR PERIODIC PULSE POWER SUPPLY |
|
Default
Input Volt:
|
208 - 240 VAC 3ø 50/60 Hz |
Regulation
|
Line and load |
Output
Voltage
|
6VDC, 12VDC, 24 VDC and 48 VDC |
Standard Features | |
Controller
|
Internal microprocessor for precise operation |
User
Control
|
Menu driven digital adjustments. |
Meters
|
Voltage: back lit LCD 3 digits Current: back lit LCD 4 digits Amp-Hour Counter: back lit LCD 8 digits |
Amp-Hour
Counter
|
Includes Reset Control |
Wave
Form Library
|
16 Programmable memory registers |
Output
Connectors
|
Industry standard bus bars |
Construction
|
Fully environmentally sealed for reliability |
Cooling
|
Forced air with thermal sense |
Non-volatile
memory
|
User settings are stored and maintained with no battery or power required. |
Calibration
|
Quick & simple front panel calibration of meters for compliance to quality and government standards |
User
Control
|
Menu driven digital adjustments |
TecNu, Inc., 66 Springer Drive, Suite 314, Highlands Ranch, CO 80126-2308. Tel: 303-471-0999; Fax: 303-471-1104.